Ultrasonic level sensing, motor pump and inlet/outlet valve control, dry-run + overflow protection, voltage cutoffs, and real-time telemetry to the Velonics One PWA. Engineered for residential, commercial, and industrial tanks from 250L to 50,000L.
Ultrasonic probe mounted in the tank lid, ranging continuously at 40 kHz. The firmware applies temperature compensation and a 5-sample median filter — so wave action, splashes, and short-term turbulence don’t move the reading.
40A solid-state relay drives the motor pump. Solenoid relays drive inlet and outlet valves. Auto-fill setpoints, manual override, scheduled runs — all enforced in firmware so a lost network connection never compromises safety.
WSS over port 8084 to our cloud MQTT broker. Retained last-will-and-testament for online/offline state. QoS 1 for commands. Connection-loss buffering for up to 24 hours of telemetry.
IP65-rated ABS housing with cable glands and gasketed lid. DIN-rail mount option for switchboards. WS2812 status LED, BOOT button for factory reset, USB-C for field-service debug.
VEL-AC100 · Rev 2.1.0 · Document VS-AC100-DS-026. Pull the PDF revision from the Velonics Doc Portal or talk to apps@velonics.io for design-in support.
A 5-unit pilot kit ships in 14 days. Apps team sets up the dashboard, walks the install, and stays on call for the first month.